LER 97-008-00:on 971011,noted that turbine stop valves closure setpoints were not properly set.Caused by procedure inadequacy.Readjusted limit switches utilizing methodology of adjusting trip setpoint while valve closes.W/971110 ltr. LER 97-008-00:on 971011,noted that turbine stop valves closure setpoints were not properly set.Caused by procedure inadequacy.Readjusted limit switches utilizing methodology of adjusting trip setpoint while valve closes.W/971110 ltr.