LER 98-020-00:on 980623,discovered previous inoperability of RCIC sys valves.Caused by initial design deficiency by misapplication or misinterpretation of design requirements. Corrected deviation in 1993.W/980723 ltr. LER 98-020-00:on 980623,discovered previous inoperability of RCIC sys valves.Caused by initial design deficiency by misapplication or misinterpretation of design requirements. Corrected deviation in 1993.W/980723 ltr.