LER 98-019-00:on 980920,containment isolation valves failed to close.Caused by solenoid failures.Solenoids which operate valves CVC-401,RC-606 & IA-909 were replaced with like replacements & evaluation was performed.With 981020 ltr. LER 98-019-00:on 980920,containment isolation valves failed to close.Caused by solenoid failures.Solenoids which operate valves CVC-401,RC-606 & IA-909 were replaced with like replacements & evaluation was performed.With 981020 ltr.